From this standpoint, CATU is fully committed to supporting you in these Next, with a completely redesigned catalogue that focuses on our products, their. The new general catalogue CATU / is available and can be downloaded in the catalogue section. Enjoy your reading! The company · Solutions. From this standpoint, CATU is fully committed to supporting Next, with a completely redesigned catalogue that focuses on our products IEC

Author: Tebar Fejinn
Country: Burma
Language: English (Spanish)
Genre: Business
Published (Last): 23 July 2005
Pages: 161
PDF File Size: 8.7 Mb
ePub File Size: 17.17 Mb
ISBN: 895-8-37489-807-2
Downloads: 61821
Price: Free* [*Free Regsitration Required]
Uploader: Tygokasa

In Europe and in the rest of the world, new clearances allow a larger population of people to perform electrical and non-electrical work on or around installations and structures, in compliance with prevention rules. This major change, supports better risk analysis and strict adherence to the supervision chain, in order to further improve operator safety. From this standpoint, CATU is fully committed to supporting you in these changes.

Firstly, with many new products designed and produced by our teams for you. Next, with a completely redesigned catalogue that focuses on our products, their functions, and their use. Finally, with new educational tools, including our convenient guides that provide simple and helpful information. It’s time to work with lasting safety, and we are here to help you, the Pros! Thank you for your confidence in us!

Complete equipment for live line LV interventions The object of the IEC is to promote international cooperation on all questions concerning standardization in the electrical fields. This resulted in regional or national working on specific standards without coordination. IEC standards were developed according to a consensus procedure and approved by recognized body. They provide an adequate answer at worldwide level. The IEC standard presents benefits to all parties involved: CATU Shows its innovation ability for the welfare of the electrical world.

Personal and cataolgue protective equipment Eyes protection 16 Head Protection 17 Insulating rubber gloves 20 Insulating boots and mats 24 Insulating platforms 25 cqtu Flash” protection 26 Workwear and other protections 30 Work at height 34 Collective Protective Equipment: PPE are cataloguw as any device or means intended to be worn xatu held by one person to protect itself against one or several risks liable to threaten its safety or its security.

  IADC SAFETY ALERTS PDF

Collective protective equipment for preventing electrical hazards contains datu the products that close off the hazard by: CPE must comply with the standards in force. PPE within the framework of electrical safety recommendations.

In practice, they define: Protection against UV radiation and ejections of solid particles. Anti-scratch, anti-impact and antichemical product treatments.

Grilamid frame Delivered in storage bag. Do not use for welding operations. MO MO One piece wraparound protection that can be worn over eyeglasses. MO Adjustable by rubber band.

Face shield adjustable on MO helmet. Protection against electric arcs of short-circuits. ABS helmet Safety industrial helmet. Standard sizes 53 to Leather trim 21 cm along the inside for added comfort. Multiple adjustments for a perfect fit headband. Reference Characteristics Deformable shock-resistant helmet with a “gutter” brim.

Size from 53 to 62 cm. Multiple adjustments for a perfect fit headband: Built-in cushion for optimum ventilation.

| Le monde de la sécurité électrique

Protects against vertical and side impacts, very well ventilated. Adjustable size from 53 to 63 cm. Designed to tear if hooked. Electrical isolation V. Head fit adjustment by milled wheel. Adjusting the height position. Chinstrap with Velcro fastening. Light wiring for a wide, short-distance beam or a long-range directional beam, or a combination of the two for optimal lighting.

Adhesive clip supplied to attach to helmet or shield. The external battery 4-pack can be carried in a pocket or around the waist. Power by 1 battery: Lighting current for a wide, short distance bean, or a long-range directional, or the combination of the two for 1 flash mode. As a result, they undergo various voltage, ageing, and mechanical testing. The gloves are individually tested and sold in a sealed plastic bag. All our gloves provide greater comfort and hygiene when used.

Glove Types, Classes, and Categories. There are 2 main types of insulating gloves: They must be used with leather glove covers for mechanical protection. They eliminate the need for overgloves. Compliance with the IEC standard. AC DC Note 1: Any category combination may be used.

All insulating gloves must be visible inspected after inflation and before each use. For Classes 1, 2, 3, and 4: Even when in storage, a glove cannot be used without having been tested within the last six months. Normal testing periods are between 30 and 90 days.

  AR 321H PDF

For Classes 0 and The tests consist of an air inflation test and a visual inspection when the glove is inflated. The dielectric test is not required, but it may be performed at the owner’s request. An inspection of the inside of the gloves is also recommended. Gloves should be stored in their packaging, without being compressed or folded.

CATU LAUNCHES AN INNOVATIVE ARC FLASH PROTECTION PRODUCT | Cicame Energie

A, B, C, D. Conventional gloves Thickness max. Long Gloves Long composite gloves for insulating the hand and arm. Reference Class Voltage Thickness max. Insulating gloves “arc flash” See page Pneumatic glove tester For compulsory control of gloves before catalkgue. Checking is done by inflating and immersing in water. Gloves box Specially designed for protecting insulating gloves.

Can be fixed on wall. The catslogue cover enables to check gloves presence. Rear loop for belt and snaps. Reference Silicon grain leather, very flexible. See the conversion table page 21 for the correct size based on the insulated glove. They bring the best held, hygiene and a greater comfort. Mittens Its fingerless gloves shape allowing to keep the maximum of dexterity.

CATU LAUNCHES AN INNOVATIVE ARC FLASH PROTECTION PRODUCT

Reference Size g CG One size 20 mm Dimensions g Cotton mittens, limit the effects of perspiration and its fingerless gloves shape allowing to keep the maximum of dexterity. Weight 23 Insulating boots and mats Made from high quality dielectrical rubber, very flexible and resistant. Insulating boots Protection against caut and touch hazardous potential gradients.

External height mm. Safety tip in technical polymer. Regulatory mark clearly indicating the mat features.

High quality dielectrical rubber. Insulating mats Adapted to High Voltage. Reference g mm M denier dust resistant nylon with PVC coating. Bags for catqlogue mats Specially designed for carrying and protecting insulating mats. Equipped with a shoulder strap.

Moulded insulating material, one-piece. Insulating platforms indoor models Top 50 x 50 cm. Adapted to the B High Voltage. Removable feet with rubber tips. Feet with rubber tips.