IEC TS Standard | Short-circuit current calculation in three-phase a.c. systems – Part 1: Factors for the calculation of short-circuit. IEC Short-Circuit Current Calculation in Three-Phase A.C. Systems Part 1: Factors for the Calculation of Short-Circuit Currents in Three-Phase A.C. IEC/TR Short-Circuit Currents in Three-Phase a.c. Systems – Part 1: Factors for the Calculation of Short-Circuit Currents According to IEC

Author: Mikanris Takus
Country: Ghana
Language: English (Spanish)
Genre: Finance
Published (Last): 19 August 2014
Pages: 353
PDF File Size: 2.3 Mb
ePub File Size: 15.29 Mb
ISBN: 329-1-47785-399-7
Downloads: 57017
Price: Free* [*Free Regsitration Required]
Uploader: Dougul

Short-circuit duty results displayed in the single line drawing Table 5: For phase TCC clipping and tick marks, EasyPower automatically selects the asymmetrical currents for low voltage circuit breakers, fuses and electromechanical relays.

Error adding the item to cart.

The IEC short-circuit results are integrated with the protective device coordination tools in EasyPower. The comparison of results is summarized below.

Motor contributions are excluded. For breaking current you can choose from 0. The faster, easier way to work with standards. Search all products by.

PD 7639-1:1994, IEC 60909-1:1991

Synchronous Generator Impedance Correction Factor The synchronous generator impedance correction factor K G for generators without unit transformers is calculated as follows per section 3. You can fault a single bus or all buses in the single-line diagram to view the short-circuit currents at the faulted buses.

Most Related  DE LIBERTATE CHRISTIANA PDF

Voltages at remote buses are also provided. What Employers need to do to Prepare.

Search results | IEC Webstore

Z S is the corrected impedance of a power station unit with LTC to the high-voltage side. Sign In Your Account. Also, all synchronous machines use the resistance R Gf iwc place of R G in accordance with section 3.

Protection against lightning – Part 2: View of the single line diagram in the time current characteristics TCC plot for protective devices. Product Reviews This product hasn’t received any reviews yet. For high voltage circuit breakers, the peak current is compared with the making capacity and the breaking current is compared with the rated breaking capacity.

This product hasn’t received any reviews 600909-1. Z THV is 6009-1 impedance of the unit transformer referred to the high-voltage side without correct factor K T. Your basket is empty. The short-circuit calculation provides the phase angle of the branch currents and the bus voltages at various equipment. EasyPower applies impedance correction factors in short circuit calculation based on IEC standard.

Subtransient impedances are used for rotating machines with the impedance correction factors. EasyPower uses the following c factors as the default for maximum and minimum short-circuit conditions. Remote Currents and Voltages Currents flowing through sources, iecc, lines, transformers and other equipment are also calculated.

Most Related  AKTA MAHKAMAH SYARIAH 1965 PDF

Display of short-circuit currents You can view the currents in various formats such as phase currents for A, B and C phases or in symmetrical components: You can obtain the following values of short-circuit currents at the fault location for both maximum and minimum short circuit currents:.

IEC-60909 Short-Circuit in EasyPower

EasyPower calculates the Peak currents i p based on section 4. You can 60990-1 a voltage sensitivity threshold in the options such that any bus with voltage below this value will be highlighted red in the single line view and shown in the voltage sensitivity report.

Case Management Boot Camp: Account Payable Best Practices: Factors for the calculation of short-circuit currents in three-phase a. Extractables and Leachables in Early Phase Development. Time-current characteristic curves showing device curves clipped at the right side and short-circuit tick marks.

Peak current based on method c: