CS S10PKH PDF

Manuals and User Guides for Panasonic CS-S10PKH. We have 1 Panasonic CS- S10PKH manual available for free PDF download: Service Manual. View and Download Panasonic CS-S10PKH service manual online. CS-S10PKH Air Conditioner pdf manual download. Also for: Cs-s13pkh, Cs-s15pkh. Panasonic CS-S10PKH Manual Online: Cs-s18pk Cs-s24pk. Indoor Electronic Controllers, Cross Flow Fan and Indoor Fan Motor Removal Procedures.

Author: Vudocage Akinora
Country: Montserrat
Language: English (Spanish)
Genre: Health and Food
Published (Last): 23 September 2017
Pages: 393
PDF File Size: 19.54 Mb
ePub File Size: 1.41 Mb
ISBN: 554-4-42649-863-3
Downloads: 12553
Price: Free* [*Free Regsitration Required]
Uploader: Kehn

Panasonic Inverter Econavi Air Conditioner (CS-S10PKH)

A place where noise prevention is taken into consideration. Attach s10poh control board cover back to the original position with screw. It must be a double pole switch with a minimum 3. Push the holdfast to the left and lift up the evapo rator.

Wiring Connection Diagram Indoor Unit 7. If control board cover is not fixed perfectly, it will cause heat-up or fire at the connection point of terminal, fire or electrical shock. Refrigeration Cycle System By default, the outdoor fan speed is set to Hi.

Most Related  ACHOIS STUDY PDF

Remove 2 caps and 2 screws at the bottom of discharge vane. When there is no signal detection continues for 20 minutes or more, the status of human absence is judged. The last error code abnormality will be stored in IC memory. Keep away from small children, the thin film may cling to nose and mouth and prevent breathing. Take care of the liquid refrigerant, it s10pkj cause frostbite. The indoor unit fan stops for 90 seconds and then blows at minimum airflow for 20 seconds.

But outdoor fan will turns off 30 seconds after compressor stops to operate. If s10pkn length is over the [piping length for additional gas], additional refrigerant should be added as shown in the table. Error Code Table Secure the cable onto the control board with the holder clamper.

LCD returns to original display after 2 seconds. If burrs is not removed, gas leakage may be caused. Pull out to remove the drain hose from the discharge grille Electrical work must be installed or serviced by a licensed electrician.

Most Related  DM74121N DATASHEET PDF

Printed Circuit Board Indoor Unit 9. Figure 8 Remove 3 caps and 4 screws at the bottom of discharge vane.

If more than one timer had been set, the upcoming timer will be display and will activated in sequence. Remove screw to remove terminal board complete.

Panasonic CS-S10PKH Manuals

Failure to heed this caution may result in electric shocks. Secure the power supply cord and connection cable onto the control board with the holder. Please wrap the insulated piping end to prevent water from going inside the piping.

Then, operation will restart after 2 minutes. Another method is intersection point of arrow mark extension.

The normal outlet air temperature and pressure of the refrigeration cycle depends on various conditions, the standard values for them are shown in the table to the right. Total Running Current Control Freeze Prevention Control 1 High fan speed o Outdoor temperature: