ASTM D6869 PDF

ASTM D Standard Test Method for Coulometric and Volumetric Determination of Moisture in Plastics Using the Karl Fischer Reaction (the Reaction of. ASTM D – 03() standard test method for coulometric and volumetric determination of moisture in plastics using the karl fischer reaction (the reaction of. ASTM D Standard Test Method for Coulometric and Volumetric Determination of Moisture in Plastics Using the Karl Fischer Reaction.

Author: Yozshushakar Arashikasa
Country: Solomon Islands
Language: English (Spanish)
Genre: Software
Published (Last): 27 October 2008
Pages: 374
PDF File Size: 2.3 Mb
ePub File Size: 13.24 Mb
ISBN: 807-7-70147-517-2
Downloads: 94225
Price: Free* [*Free Regsitration Required]
Uploader: Samuramar

Sample containers must be adequately dried and the environment in which sampling is performed must not add additional moisture to the sample.

The sample container 6d869 be properly sealed to prevent moisture pick-up before testing. Permission rights to photocopy the standard may also be secured from the ASTM website www. Current edition approved Sept.

Knowledge of the moisture content can be important since some polymers degrade when molded wet resulting in reduced properties.

ASTM D – MOISTURE CONTENT BY KARL FISCHER

dd6869 Individual reprints single or multiple copies of this standard may be obtained by contacting ASTM at the above address or at phonefaxor service astm. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

It is permissible to use similar hydrates to check instrument performance.

Jena, September 26, — 24 hours of continuous operation, samples, without monitoring and in minimum space: High moisture content causes surface imperfections that is, splay or bubbling or degradation by hydrolysis.

Most Related  BUNDESPFLEGESATZVERORDNUNG 2011 PDF

The permanganate index is an assessment of water quality typically used for freshwater and treated drinking waters. Spectro Scientific has introduced an upgrade to its FieldLab 58 consisting of a more powerful X-ray fluorescence XRF module and newly designed filter that significantly improve the limits of detection for wear metal elements in oil.

Moisture Content by Karl Fischer ASTM D

To request a quote for this test or others Click Here. Due to copyright restrictions, we are not able to provide copies of standards.

Sample size shall be adjusted to obtain an accurate moisture measurement. No comments were found for ASTM D – 03 standard test method for coulometric and volumetric determination of moisture in plastics using the karl fischer reaction the reaction of iodine with water.

It is the responsibility of the user of this standard to establish appropriate safety and aatm practices and determine the applicability of regulatory limitations prior to use. As solutions age, viscosity will increase and solution color will turn dark.

Moisture Content by Karl Fischer

It involves the determination of oxidizability, also known as oxygen O2 demand, by potassium permanganate ISO method If the cell potential shows a negative value, indicating that the anode solution contains excess iodine, add approximately 50 to ? ASTM D – 03 standard test method for coulometric and volumetric determination of moisture in plastics using the karl fischer reaction the reaction of iodine with water 0.

Most Related  ANTENNA THEORY AND PRACTICE BY RAJESWARI CHATTERJEE PDF

Moisture will affect the processability of some plastics.

Karl Fischer is used to determine the water content of samples. If the temperature sstm too low or the retention time too short all of the water might not be driven off. Low moisture with high temperature causes polymerization. The instrument is now ready for sample analysis. The physical properties of some plastics are affected by the moisture content.

ASTM D6869

Prepare the instrument as detailed in Ast, Two methods of checking the instrument are listed here, a micro-capillary method and a sodium citrate method.

High moisture content causes surface imperfections that is, splay or bubbling or degradation by hydrolysis.

NOTE 4—Another permissible method, which uses a micro syringe, is described in section 4. Astj is probably caused by the generation of water due to thermal decomposition or solid phase polymerization of the sample.

Selection of Optimum Heating Temperature is discussed below. It can be more accurate than simple weight loss because in the weight loss method volatiles other than water can be lost which is translated into adtm artificially high water content.

Sampling, Test Specimens, and Test Units 9. This is how compEAct works — a sulfur and nitrogen analyzer from Analytik Jena developed for the petrochemical industry.